DEMO — All data is fictional and for demonstration purposes only. No real client data is shown.

Meridian Industrial Estate

Brisbane QLD

120 kW solar · 3 sub-meters · Platform Demo Showcase

Analysis window

Grid Import

9.5 MWh

Grid Export

0.9 MWh

Solar Generated

2.2 MWh

Solar Used On-Site

1.3 MWh

Total Consumed

10.8 MWh

Est. Cost Saving

$430

1Energy Overview — Multi-Series Area Chart
Overlaid areas for solar generation, grid export, grid import, and total consumption over the selected period
2Hourly Demand Profile — Min / Avg / Max Band
Demand band across all days in the period
3Load Duration Curve
All readings sorted highest → lowest — how much time at each demand level
4Day vs Night Split — Donut
Energy consumed during solar hours vs night hours
Day (6am–6pm)

6.5 MWh

60.1% of total

Night (6pm–6am)

4.3 MWh

39.9% of total

5Tariff Band Breakdown — Pie + Bars
Peak / shoulder / off-peak kWh split with estimated costs
Peak (2–8pm)2987 kWh · $1045
Shoulder AM1742 kWh · $383
Shoulder PM2085 kWh · $459
Off-Peak2527 kWh · $202
Est. Total Cost$2090
6Weekday vs Weekend Profile
Average hourly demand comparison — industrial load pattern
7Energy Heatmap — 7-Day × 24-Hour Grid
Average demand intensity by day-of-week and hour — colour = kW
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Mon
Tue
Wed
Thu
Fri
Sat
Sun
Low
High (46 kW)
8Self-Sufficiency & Grid Dependence — Area Ratio
Daily solar coverage vs grid reliance stacked 100%
9Cumulative Energy Curves
Running totals for import, export, and solar generation
10Rolling 7-Day Average + Anomaly Flags
Daily consumption with 7-day moving average — red dots = statistical anomalies (|z| > 1.8)
Anomaly points = readings more than 1.8 standard deviations from the running mean
11Solar Yield & Performance Ratio
Actual vs expected generation — PR = actual ÷ (capacity × peak_hrs × 0.8)
12Net Energy Position — Hourly Bar
Positive = solar surplus exported; negative = grid draw
Solar surplus
Grid draw
13Solar vs Grid Scatter Plot
Correlation between solar output and grid import intensity
14Daily Demand Range — Min / Avg / Max
Candlestick-style bar showing daily kW spread
15Baseload Estimate — Night-time Floor
Minimum overnight demand trend — identifies always-on loads
16Demand Percentile Distribution
P10–P99 demand levels with key statistics

24.2 kW

Mean

22.0 kW

Median (P50)

45.9 kW

P95

10.7 kW

Std Dev

17Sub-Meter Breakdown — Stacked Bar
3 sub-meters contributing to total site consumption per day
18KPI Ring Gauges
Period summary — self-sufficiency, grid dependence, export efficiency
12%
Self- Sufficiency
88%
Grid Dependence
41%
Export Efficiency

11.9%

Self-Sufficiency

Solar covers this % of site load

88.1%

Grid Dependence

This % of load still needs grid

41.0%

Export Efficiency

Of solar generated, this % exports

19Weather & Solar Irradiance — Multi-Site
Current conditions across all monitored locations
SiteLocationConditionsTempHumidityCloud CoverSolar Impact
Meridian Main Campus
Rocklea, QLD
Partly cloudy
26.1°C
74%
29%
90% — Excellent
North Warehouse
Acacia Ridge, QLD
Scattered clouds
28.2°C
53%
39%
67% — Good
South Factory
Salisbury, QLD
Mostly sunny
25.3°C
52%
14%
93% — Excellent
20Hardware Inventory — Device Status
Monitored devices with connectivity status and firmware versions
Device NameModelLocationIMEIStatusLast SeenFirmware
Main Incomer MonitorWattwatchers 6M4Main Switchboard350000000000001
Online
2 min ago
v4.2.1
Solar Array InverterSMA Sunny Tripower 25Roof Plant Room350000000000002
Online
1 min ago
v3.8.4
North Sub-MeterConexie CM-3PDB-N1350000000000003
Warning
18 min ago
v2.1.0
South Factory MeterConexie CM-3PDB-S2350000000000004
Offline
4 hrs ago
v2.0.8
21Support Tickets
Open and recent support requests with priority and status
Ticket IDTitlePriorityStatusCreatedAssignee
TKT-1042North Sub-Meter reporting intermittent data gaps
High
In Progress
2026-04-14J. Nguyen
TKT-1038South Factory Meter offline — check comms cable
Critical
Open
2026-04-13M. Torres
TKT-1031Solar export spike anomaly on 10 Apr — investigate inverter
Medium
Resolved
2026-04-10J. Nguyen
TKT-1025Quarterly report generation failed — timezone mismatch
Low
Closed
2026-04-05A. Patel
TKT-1019Set up demand threshold alerts for peak tariff windows
Medium
In Progress
2026-04-01M. Torres
Total Invoiced

$11,370.00

6 invoices

Total Paid

$8,840.00

4 invoices paid

Outstanding

$2,530.00

2 invoices pending

22Billing Summary + Invoice Table
Invoice history with payment status
Invoice #DescriptionDateAmountStatus
INV-2026-006Platform subscription — Q2 20262026-04-01$1,850.00
Outstanding
INV-2026-005Hardware installation — South Factory expansion2026-03-15$3,240.00
Paid
INV-2026-004Platform subscription — Q1 20262026-01-01$1,850.00
Paid
INV-2025-012Custom report integration — Xero API2025-12-10$2,100.00
Paid
INV-2025-011Platform subscription — Q4 20252025-10-01$1,650.00
Paid
INV-2025-009On-site training session (2 hrs) + config review2025-09-20$680.00
Overdue
23Alert Feed
System alerts — threshold breaches, device issues, anomalies

Device Offline: South Factory Meter

4 hrs ago

Conexie CM-3P at DB-S2 has not reported in 4 hours. Last reading: 12 Apr 10:22.

Demand Threshold Breach

2 hrs ago

Peak demand reached 118.4 kW at 16:35 today — exceeding the 110 kW alert threshold.

North Sub-Meter: Intermittent Gaps

18 min ago

Data gaps of 15–45 min detected across 3 readings today. May indicate comms issue.

Solar Export Anomaly — Resolved

2 days ago

Spike of 94.2 kW export on 10 Apr traced to inverter config reset. Firmware updated.

DEMO MODE — Meridian Industrial Estate is a fictional company. All data is generated and does not represent any real installation.

Conexie Platform · 30-day analysis window · 30 days of data · 23 visualization types